BJNCM - PIANO BATTERY HS
- MSDS: BJNCM
- Manufacturer: BST SYSTEMS INC
- Product Name: PIANO BATTERY HS
- National Stock Number: 6135-01-093-7426
Product Identification
Product ID:PIANO BATTERY HS
MSDS Date:01/05/1990
FSC:6135
NIIN:01-093-7426
Kit Part:Y
MSDS Number: BJNCM
Responsible Party
PLAINFIELD, CT 06374
US
Emergency Phone: 203-564-4078
Info Phone: 203-564-4078
Cage: 62339
Contractor
Telephone: 203-564-4078
Cage: 62339
Ingredients
SILVER (SARA III)
CAS: 7440-22-4
RTECS: VW3500000
OSHA PEL 0.01 MG/M3
ACGIH TLV: 0.1 MG/M3; 9192
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
ZINC OXIDE
CAS: 1314-13-2
RTECS: ZH4810000
OSHA PEL 15MG/M3 TDUST/5 FUME
ACGIH TLV: 10MG/M3 TDUST; 9293
MERCURIC OXIDE (SARA III)
CAS: 21908-53-2
RTECS: OW8750000
OSHA PEL 0.1 MG HG/M3;SKIN;C
ACGIH TLV: 0.1 MG HG/M3; 9192
POLYSULFONE
CAS: 25154-01-2
POTASSIUM HYDROXIDE
CAS: 1310-58-3
OSHA PEL 2 MG/M3, C
ACGIH TLV: 2 MG/M3, C
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:KOH - CONTACT WITH SKIN CAUSES BURNS.
INHAL:MIST MAY DAMAGE RESPIRATORY TRACT. INGEST:CAUSES THROAT &
GASTRO-RESPIRATORY BURNS.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHAL:REMOVE FROM EXPOSURE, GET MEDICAL HELP. SKIN:REMOVE
CONTAMINATED CLOTHING AND WASH WITH WATER. EYES:FLUSH WITH WATER AT
LEAST 15 MIN, GET MEDICAL HELP. INGEST:DRINK WATER. DO NOT INDUCE
VOMITING , GET MEDICAL HELP.
Fire Fighting
Extinguishing Media:WATER
Fire Fighting Procedures:TO PREVENT EXPOSURE TO MERCURY VAPORS WHICH
MAY BE LIBERATED DURING A FIRE, WEAR NIOSH/MSHA APPROVED SCBA AND
FULL PROTECTIVE EQUIPMENT.
Unusual Fire/Explosion Hazard:FIRE MAY LIBERATE TOX MERCURY FUMES&HAZ
FLUORINE CMPNDS;INCOMPLETE BURNING OF POLYSULFONE MAY RELS
CO&CO*2;CONTACT OF KOH WITH METALS CAN RELEASE HYDROGEN GAS.
Accidental Release
Spill Release Procedures:FOR KOH SPILL - WEAR PROTECTIVE CLOTHING
INCLUDING GLOVES, GOGGLES. AVOID CONTACT WITH SKIN. CONTAIN SPILL
AND NEUTRALIZE WITH WEAK ACID (VINEGAR, BORIC ACID) AND FLUSH WITH
WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DRY BATTERIES TO BE STORED AT TEMPS
BETWEEN 0-40F(OPTIMIM). WET BATTERIES NOT REQD FOR 30 DAYS/LONGER
SHOULD BE DISCHARGED PER MFR (SEE OTHER PRECAU)
Other Precautions:HDLG/STOR PREC:OPERATING PROCEDURES AND STORED AT
TEMPS BETWEEN 0-40F.
Exposure Controls
Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE
FOR EXPOSURE OF CONCERN .
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:RUBBER OR PLASTIC GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:LIQUID RESISTANT APRONS; SAFETY EYE
WASH/SHOWER STATIONS.
Work Hygienic Practices:AVOID DIRECT SKIN CONTACT W/KOH; TO REDUCE
ELECTROCUTION RISK, ALL ASSOC TOOLS SHOULD BE INSULATED. (SEE SUPP
DATA)
Supplemental Safety and Health
HYGIENE PRACT:WASH THOROUGHLY AFTER USE AND BEFORE EATING, SMOKING OR
USING SANITARY FACILITIES .
Chemical Properties
Appearance and Odor:CELL-RECTANGULAR CUBE, CLEAR AMBER COLOR WITH
MULTIPLE ELECTRODES VISIBLE.
Stability
Stability Indicator/Materials to Avoid:YES
HYDROGEN PEROXIDE, AMINES, REDUCING AGENTS, MOLTEN ALKALI METALS,
ALUMINUM AND TIN (KOH ONLY).
Stability Condition to Avoid:AVOID STORAGE TEMPS GREATER THAN 70F.
Hazardous Decomposition Products:TEMPS HIGHER THAN 962C,AG*20 FUME MAY
BE EVOLVED;KOH&METALS MAY LIB H2 GAS,HF MAY BE FORMED WHEN TEFLON
BURNS.
Disposal
Waste Disposal Methods:SPENT (USED) BATTERIES SHOULD BE COLLECTED FOR
PRECIOUS METALS RECLAMATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.